| Name | Nabatoff Vein Stripper |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Competitor | ;FB030R;SU11770;160120;160-120;099500;09-9500;0995-00; |
| Specialty | General Instruments-Suction Tubes, Needles & Probes – Vein Strippers |
| Material Finish | Stainless Steel/Plastic |
| Grade | Premium Operating Room |
| Units of Measurement | Set |
| Manufacturer | Ophthalmic Zone |
| Sterility | Non-Sterile |
| Usage | Reusable |
Vein Stripper
Vein Stripper
complete set in stainless steel sterilizing case, includes: traction cable, handle, plastic probe tip, metal probe tip, olive adaptors (6.0 mm, 9.0 mm & 12.0 mm)
Nabatoff Vein Stripper is a complete set loaded in a stainless steel sterilizing case that includes several tools such as traction cable, handle, probe tips, and olive adaptors. This instrument is typically used during procedures that involve the removal of varicose veins. Once an incision is made around the area, the wire is inserted into the vein and tied so that the vein can be pulled out.
SKU:
OZ-01-878
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Vein Stripper” Cancel reply
Related products
Frazier Suction Tube – Extra-Long
Frazier Suction Tube - Extra-Long
extra-long, angled, w/ finger cut-off, 7-1/8" (18.1 cm) working length
Frazier Suction Tube is an extra-long style consisting of a 7 1/8" working length. The handle contains a finger cut-off to rest the finger on, and the tube is angled near the base. The intended purpose of this instrument is to eliminate the operating area of any fluids or substances that may be present so that the surgeon is provided with a clear view. Thus, the suction tube may be used for general surgeries and even gynecological procedures.
Frazier Suction Tube – Semi-Rigid W/ Slot
Frazier Suction Tube - Semi-Rigid W/ Slot
angled, semi-rigid w/ slot, 5-1/2" (14.0 cm) working length
Frazier Suction Tube is semi-rigid with a slot on the handle. The tube is angled and is primarily utilized during general surgeries to remove any fluids or blood that may occupy the surgical site obstructing the surgeon's view. In this case, the thin diameter of the tube, in addition to the 5 ½" length, is able to enter small areas that require matter to be eliminated.
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet
Frazier Suction Tube Stylet is a thin wire device that serves the purpose of clearing any contents that remain inside the Frazier Suction Tube. All of the sizes offered of this stylet are specifically designed to enter each of the various sizes and thickness of the Angled Frazier Suction Tube with finger cut-off and 4" working length.
Probe W/ Eye
Probe W/ Eye
stainless steel
Probe is a slender stainless steel device that ranges from 4 ½" to 10" in total length and contains an eye opening on one end. The popularity of this probe arises in its ability to explore lesions or body cavities to display the underlying tissues that need to be examined.
Probe W/ Eye – usa pattern
usa pattern
Probe With Eye is a USA Pattern that is available in stainless steel or sterling silver material and a variety of different lengths. The slender rod contains an eye opening on one end near the handle that may be useful if ligatures need to be carried. Additionally, this probe is typically used during general surgeries to examine body tissues or for situations such as detecting foreign bodies.
Suction Tube
Suction Tube
9" (22.9 cm) overall length
Andrews-Pynchon Suction Tube is designed with a tapered handle to create a comfortable and secure grip when held. The suction tube itself is slightly curved and contains either a removable tip or a removable shaft to assist with different suction processes throughout a surgical procedure. This 9" long instrument is ideal for removing fluid or blood that may interfere with the operating area.
Suction Tube
Suction Tube
offset suction tip holes, 3" (7.5 cm) working length
Brackman Suction Tube contains a thumb plate on the handle to rest the finger on and also to control the bypass hole. The tube itself is either 5 or 7 French and has offset suction tip holes. These fine suction tips are designed to be used in surgeries, such as myringoplasty, for areas that are narrow or more delicate in order to avoid excess suction.
Tongue Tie – Plain Point
Tongue Tie - Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.

Reviews
There are no reviews yet.